T1 - Comparative left ventricular function following atrial, septal, and apical single chamber heart pacing in the young
AU - Karpawich, Peter P.
AU - Mital, Seema
PY - 1997/8
Y1 - 1997/8
N2 - Ventricular pacing, typically initiated from a RV apical electrade, inherently causes abnormal biventricular activation, decreases LV function, and causes histopathological changes. Since pacing initiated in childhood can be expected to have a more protracted course compared with the adult, the consequences of this alteration in LV hemodynamics gain added significance among the young pacemaker recipient. The purpose of this study was to evaluate the potential of improving paced LV function by a septal electrode implant site. Acute alterations in cardiac index, LV pressure, and contraction indices, including dP/dt, Vmax, and Vpm, were compared among 22 patients (median age 10 years) with normal cardiac anatomy during intracardiac electrophysiological studies. LV hemodynamics were measured during intrinsic rhythms and following 15 minutes of atrial, RV apical, and septal pacing at an appropriate exercise rate for age of 150 ppm. Results showed a significant decrease in LV dP/dt, Vmax, and Vpm, and increase in LV end-diastolic pressure only with apical pacing. Septal pacing, in spite of loss of any atrial contribution to ventricular filling, maintained comparable indices with intrinsic and atrial paced rhythms. This study demonstrates that normalized LV function is maintained by septal and deteriorates with apical pacing acutely among young, nonischemic hearts. Continued evaluation of appropriate pacing electrode designs to permit septal implant is needed to ensure optimal chronically paced LV function.
AB - Ventricular pacing, typically initiated from a RV apical electrade, inherently causes abnormal biventricular activation, decreases LV function, and causes histopathological changes. Since pacing initiated in childhood can be expected to have a more protracted course compared with the adult, the consequences of this alteration in LV hemodynamics gain added significance among the young pacemaker recipient. The purpose of this study was to evaluate the potential of improving paced LV function by a septal electrode implant site. Acute alterations in cardiac index, LV pressure, and contraction indices, including dP/dt, Vmax, and Vpm, were compared among 22 patients (median age 10 years) with normal cardiac anatomy during intracardiac electrophysiological studies. LV hemodynamics were measured during intrinsic rhythms and following 15 minutes of atrial, RV apical, and septal pacing at an appropriate exercise rate for age of 150 ppm. Results showed a significant decrease in LV dP/dt, Vmax, and Vpm, and increase in LV end-diastolic pressure only with apical pacing. Septal pacing, in spite of loss of any atrial contribution to ventricular filling, maintained comparable indices with intrinsic and atrial paced rhythms. This study demonstrates that normalized LV function is maintained by septal and deteriorates with apical pacing acutely among young, nonischemic hearts. Continued evaluation of appropriate pacing electrode designs to permit septal implant is needed to ensure optimal chronically paced LV function.
KW - Hemodynamics
KW - Pacing
KW - Septum
KW - Ventricular function
UR - http://www.scopus.com/inward/record.url?scp=0030743945&partnerID=8YFLogxK
U2 - 10.1111/j.1540-8159.1997.tb03605.x
DO - 10.1111/j.1540-8159.1997.tb03605.x
M3 - Review article
C2 - 9272537
AN - SCOPUS:0030743945
SN - 0147-8389
VL - 20
SP - 1983
EP - 1988
JO - Pacing and Clinical Electrophysiology
JF - Pacing and Clinical Electrophysiology
IS - 8 I
ER -