TY - JOUR
T1 - Percutaneous Closure of Perimembranous Ventricular Septal Defects Using the Second-Generation Amplatzer Vascular Occluders
AU - Ebeid, Makram R.
AU - Batlivala, Sarosh P.
AU - Salazar, Jorge D.
AU - Eddine, Ahmad Charaf
AU - Aggarwal, Avichal
AU - Dodge-Khatami, Ali
AU - Maposa, Douglas
AU - Taylor, Mary B.
N1 - Publisher Copyright:
© 2016 Elsevier Inc.
PY - 2016/1/1
Y1 - 2016/1/1
N2 - Earlier attempts at percutaneous closure of perimembranous ventricular septal defects (Pm VSDs) were abandoned because of incidence of heart block likely as a result of device rigidity and/or oversizing. This is retrospective review and data reporting of patients who underwent percutaneous closure using the softer second-generation Amplatzer vascular occluders; namely the Amplatzer vascular plug, second generation, (AVP II) and the Amplatzer duct occluder, second generation (ADO II) in our institution. A total of 20 patients were identified; AVP II was used in 9 patients and ADO II in 11 patients. Median weight was 13.45 kg (range 6.5 to 76); age 28.5 months (range 11 to 352). After procedure, 4 were noted to have aortic insufficiency; trivial in 3 and mild in 1 (unrelated to the device). Mild tricuspid regurgitation possibly device or procedure related was seen in 4. Residual flow through the device was common after procedure and disappeared in all but 3, graded as trivial in 1, small in 2. Average follow-up period was 7.54 months ± 7.5 (1 day to 25 months). There was no incidence of heart block, bacterial endocarditis, hemolysis, device embolization, or fracture. The aortic insufficiency resolved in 1 patient and was estimated to be trivial in the remaining 3 patients. In conclusion, percutaneous closure of Pm VSDs using the softer new generation devices as the AVP II and the ADO II is feasible and safe. Longer follow-up and larger series are needed.
AB - Earlier attempts at percutaneous closure of perimembranous ventricular septal defects (Pm VSDs) were abandoned because of incidence of heart block likely as a result of device rigidity and/or oversizing. This is retrospective review and data reporting of patients who underwent percutaneous closure using the softer second-generation Amplatzer vascular occluders; namely the Amplatzer vascular plug, second generation, (AVP II) and the Amplatzer duct occluder, second generation (ADO II) in our institution. A total of 20 patients were identified; AVP II was used in 9 patients and ADO II in 11 patients. Median weight was 13.45 kg (range 6.5 to 76); age 28.5 months (range 11 to 352). After procedure, 4 were noted to have aortic insufficiency; trivial in 3 and mild in 1 (unrelated to the device). Mild tricuspid regurgitation possibly device or procedure related was seen in 4. Residual flow through the device was common after procedure and disappeared in all but 3, graded as trivial in 1, small in 2. Average follow-up period was 7.54 months ± 7.5 (1 day to 25 months). There was no incidence of heart block, bacterial endocarditis, hemolysis, device embolization, or fracture. The aortic insufficiency resolved in 1 patient and was estimated to be trivial in the remaining 3 patients. In conclusion, percutaneous closure of Pm VSDs using the softer new generation devices as the AVP II and the ADO II is feasible and safe. Longer follow-up and larger series are needed.
UR - http://www.scopus.com/inward/record.url?scp=84959196133&partnerID=8YFLogxK
U2 - 10.1016/j.amjcard.2015.10.010
DO - 10.1016/j.amjcard.2015.10.010
M3 - Article
C2 - 26589818
AN - SCOPUS:84959196133
SN - 0002-9149
VL - 117
SP - 127
EP - 130
JO - The American Journal of Cardiology
JF - The American Journal of Cardiology