TY - JOUR
T1 - Quantification of microRNAs directly from body fluids using a base-stacking isothermal amplification method in a point-of-care device
AU - Williams, Maggie R.
AU - Stedtfeld, Robert D.
AU - Stedtfeld, Tiffany M.
AU - Tiedje, James M.
AU - Hashsham, Syed A.
N1 - Funding Information:
This work was supported by the National Institute of Environmental Health Sciences Superfund Research Program (NIEHS SRP P42ES004911) and the twenty-first Century Michigan Economic Development Corporation (GR-476 PO 085P3000517).
Publisher Copyright:
© 2017, Springer Science+Business Media New York.
PY - 2017/9/1
Y1 - 2017/9/1
N2 - MicroRNAs have been proposed to be a class of biomarkers of disease as expression levels are significantly altered in various tissues and body fluids when compared to healthy controls. As such, the detection and quantification of microRNAs is imperative. While many methods have been established for quantification of microRNAs, they typically rely on time consuming handling such as RNA extraction, purification, or ligation. Here we describe a novel method for quantification of microRNAs using direct amplification in body fluids without upstream sample preparation. Tested with a point-of-care device (termed Gene-Z), the presence of microRNA promotes base-stacking hybridization, and subsequent amplification between two universal strands. The base-stacking approach, which was achieved in <60 min, provided a sensitivity of 1.4 fmol per reaction. Tested in various percentages of whole blood, plasma, and faeces, precision (coefficient of variation = 2.6%) was maintained and comparable to amplification in pristine samples. Overall, the developed method represents a significant step towards rapid, one-step detection of microRNAs.
AB - MicroRNAs have been proposed to be a class of biomarkers of disease as expression levels are significantly altered in various tissues and body fluids when compared to healthy controls. As such, the detection and quantification of microRNAs is imperative. While many methods have been established for quantification of microRNAs, they typically rely on time consuming handling such as RNA extraction, purification, or ligation. Here we describe a novel method for quantification of microRNAs using direct amplification in body fluids without upstream sample preparation. Tested with a point-of-care device (termed Gene-Z), the presence of microRNA promotes base-stacking hybridization, and subsequent amplification between two universal strands. The base-stacking approach, which was achieved in <60 min, provided a sensitivity of 1.4 fmol per reaction. Tested in various percentages of whole blood, plasma, and faeces, precision (coefficient of variation = 2.6%) was maintained and comparable to amplification in pristine samples. Overall, the developed method represents a significant step towards rapid, one-step detection of microRNAs.
KW - Direct amplification
KW - Isothermal amplification
KW - MicroRNA quantification
KW - Point-of-care diagnostics
UR - http://www.scopus.com/inward/record.url?scp=85019733283&partnerID=8YFLogxK
U2 - 10.1007/s10544-017-0191-2
DO - 10.1007/s10544-017-0191-2
M3 - Article
C2 - 28536858
AN - SCOPUS:85019733283
VL - 19
JO - Biomedical Microdevices
JF - Biomedical Microdevices
SN - 1387-2176
IS - 3
M1 - 45