TY - JOUR
T1 - Seismic response of buried reservoir structures
T2 - a comparison of numerical simulations with centrifuge experiments
AU - Esmaeilzadeh Seylabi, E.
AU - Jeong, C.
AU - Dashti, S.
AU - Hushmand, A.
AU - Taciroglu, E.
N1 - Publisher Copyright:
© 2018 Elsevier Ltd
PY - 2018/6
Y1 - 2018/6
N2 - Centrifuge experiments on seismic performance of relatively stiff underground reservoir structures in dry sand are modeled numerically. The capabilities of numerical simulations with calibrated equivalent linear soil properties in capturing the main features of experimentally measured responses are explored for both low and high amplitude earthquake motions. The scattering effects of the centrifuge container boundaries are also investigated by modeling the same soil deposit resting on an elastic bedrock and extending infinitely laterally, using the domain reduction method. It is observed that the calibrated equivalent linear soil models perform well in predicting accelerations, racking, and bending strains on the buried structure, even for high amplitude motions for which significant soil nonlinearity is expected. While not as accurate, the seismic lateral earth pressures predicted with these models are in fair agreement with direct measurements made with tactile sensors. The mismatches in earth pressures are likely due to local nonlinearities of soil and frictional contact, which were absent from the numerical models. It is also observed that the scattering effects of the container boundaries become more significant closer to the soil surface, and their characteristics are seen to depend on both the side boundaries and the embedded structure's stiffness.
AB - Centrifuge experiments on seismic performance of relatively stiff underground reservoir structures in dry sand are modeled numerically. The capabilities of numerical simulations with calibrated equivalent linear soil properties in capturing the main features of experimentally measured responses are explored for both low and high amplitude earthquake motions. The scattering effects of the centrifuge container boundaries are also investigated by modeling the same soil deposit resting on an elastic bedrock and extending infinitely laterally, using the domain reduction method. It is observed that the calibrated equivalent linear soil models perform well in predicting accelerations, racking, and bending strains on the buried structure, even for high amplitude motions for which significant soil nonlinearity is expected. While not as accurate, the seismic lateral earth pressures predicted with these models are in fair agreement with direct measurements made with tactile sensors. The mismatches in earth pressures are likely due to local nonlinearities of soil and frictional contact, which were absent from the numerical models. It is also observed that the scattering effects of the container boundaries become more significant closer to the soil surface, and their characteristics are seen to depend on both the side boundaries and the embedded structure's stiffness.
KW - Centrifuge testing
KW - Domain reduction method
KW - Equivalent linear soil
KW - Perfectly matched layer
KW - Principal component analysis
KW - Soil-structure interaction
KW - Underground reservoir structures
UR - http://www.scopus.com/inward/record.url?scp=85043977620&partnerID=8YFLogxK
U2 - 10.1016/j.soildyn.2018.03.003
DO - 10.1016/j.soildyn.2018.03.003
M3 - Article
AN - SCOPUS:85043977620
SN - 0267-7261
VL - 109
SP - 89
EP - 101
JO - Soil Dynamics and Earthquake Engineering
JF - Soil Dynamics and Earthquake Engineering
ER -