TY - JOUR
T1 - Surface characterization and cytotoxicity response of biodegradable magnesium alloys
AU - Pompa, Luis
AU - Rahman, Zia Ur
AU - Munoz, Edgar
AU - Haider, Waseem
N1 - Publisher Copyright:
© 2015 Elsevier B.V. All rights reserved.
PY - 2015/4/1
Y1 - 2015/4/1
N2 - Magnesium alloys have raised an immense amount of interest to many researchers because of their evolution as a new kind of third generation materials. Due to their biocompatibility, density, and mechanical properties, magnesium alloys are frequently reported as prospective biodegradable implant materials. Moreover, magnesium alloys experience a natural phenomenon to biodegrade in aqueous solutions due to its corrosion activity, which is excellent for orthopedic and cardiovascular applications. However, a major concern with such alloys is fast and non-uniform corrosion degradation. Controlling the degradation rate in the physiological environment determines the success of biodegradable implants. In this investigation, three different grades of magnesium alloys: AZ31B, AZ91E and ZK60A were studied for their corrosion resistance and biocompatibility. Scanning electron microscopy, energy dispersive spectroscopy, atomic force microscopy and contact angle meter are used to study surface morphology, chemistry, roughness and wettability, respectively. Additionally, the cytotoxicity of the leached metal ions was evaluated by using a tetrazolium based bio-assay, MTS.
AB - Magnesium alloys have raised an immense amount of interest to many researchers because of their evolution as a new kind of third generation materials. Due to their biocompatibility, density, and mechanical properties, magnesium alloys are frequently reported as prospective biodegradable implant materials. Moreover, magnesium alloys experience a natural phenomenon to biodegrade in aqueous solutions due to its corrosion activity, which is excellent for orthopedic and cardiovascular applications. However, a major concern with such alloys is fast and non-uniform corrosion degradation. Controlling the degradation rate in the physiological environment determines the success of biodegradable implants. In this investigation, three different grades of magnesium alloys: AZ31B, AZ91E and ZK60A were studied for their corrosion resistance and biocompatibility. Scanning electron microscopy, energy dispersive spectroscopy, atomic force microscopy and contact angle meter are used to study surface morphology, chemistry, roughness and wettability, respectively. Additionally, the cytotoxicity of the leached metal ions was evaluated by using a tetrazolium based bio-assay, MTS.
KW - Biodegradable
KW - Corrosion
KW - Cytotoxicity
KW - Magnesium
KW - Surface treatment
UR - http://www.scopus.com/inward/record.url?scp=84921950815&partnerID=8YFLogxK
U2 - 10.1016/j.msec.2015.01.017
DO - 10.1016/j.msec.2015.01.017
M3 - Article
C2 - 25687006
AN - SCOPUS:84921950815
VL - 49
SP - 761
EP - 768
JO - Materials Science and Engineering C
JF - Materials Science and Engineering C
SN - 0928-4931
ER -